AZURA R VWD 2.1L variable wavelength detector with flow cell. Precise UV/VIS detection for HPLC and UHPLC analyses in chromatography workflows. Detector Type: Variable multi-wavelength detector, Conductivity monitor, pH Monitor Detection Channels: 4x UV/VIS, 1x Conductivity, 1x Temperature, 1x pH Wavelength Range: 190-900 nm Light Source: High brightness deuterium (D₂) lamp and halogen lamp with integrated GLP chip Flow Cell: Not included Display: Mobile Control (optional) Conductivity Range: 0.1-1000 mS/cm pH Measurement Range: 0-14 Wavelength Accuracy: ± 1.5 nm (verification with integrated holmium oxide filter) Wavelength Precision: 0.4 nm (ASTM E275-93) Conductivity Accuracy: ± 2 % or ± 0.5 mS/cm (whatever is greater) pH Measurement Accuracy: ± 0.1 (pH 2-12) Temperature Range: 1-99 °C Temperature Accuracy: ± 1.5 °C (4-40 °C) Wavelength Verification: Internal holmium filter Leak Sensor: Yes, Adjustable sensitivity GLP Report: Lamp recognition, Operating hours, Light source operating hours, Flow cell recognition Maintenance: Frontally accessible deuterium and halogen lamp, as well as flow cell Spectral Bandwidth: 6 nm at Hα line (FWHM) Baseline Noise Level (Test Cell, 254 nm, ASTM E1657-98): ± 7.5 µAU Drift (254 nm, ASTM E1657-98): 200 µAU/h Linearity (274 nm, ASTM E1657-98): > 2.5 AU Max. Data Rate: 100 Hz (LAN, 1 UV/VIS channel), 5 Hz (LAN, 4 UV/VIS channels with Dl=100 nm) Time Constants: 0.01 / 0.02 / 0.05 / 0.1 / 0.2 / 0.5 / 1.0 / 2.0 / 5.0 / 10.0 s Integration Time: Automatic

Ficha técnica del fabricante →

Especificaciones técnicas

Detector TypeVariable multi-wavelength detector, Conductivity monitor, pH Monitor
Detection Channels4x UV/VIS, 1x Conductivity, 1x Temperature, 1x pH
Wavelength Range190-900 nm
Light SourceHigh brightness deuterium (D₂) lamp and halogen lamp with integrated GLP chip
Flow CellNot included
DisplayMobile Control (optional)
Conductivity Range0.1-1000 mS/cm
pH Measurement Range0-14
Wavelength Accuracy± 1.5 nm (verification with integrated holmium oxide filter)
Wavelength Precision0.4 nm (ASTM E275-93)
Conductivity Accuracy± 2 % or ± 0.5 mS/cm (whatever is greater)
pH Measurement Accuracy± 0.1 (pH 2-12)
Temperature Range1-99 °C
Temperature Accuracy± 1.5 °C (4-40 °C)
Wavelength VerificationInternal holmium filter
Leak SensorYes, Adjustable sensitivity
GLP ReportLamp recognition, Operating hours, Light source operating hours, Flow cell recognition
MaintenanceFrontally accessible deuterium and halogen lamp, as well as flow cell
Spectral Bandwidth6 nm at Hα line (FWHM)
Baseline Noise Level (Test Cell, 254 nm, ASTM E1657-98)± 7.5 µAU
Drift (254 nm, ASTM E1657-98)200 µAU/h
Linearity (274 nm, ASTM E1657-98)> 2.5 AU
Max. Data Rate100 Hz (LAN, 1 UV/VIS channel), 5 Hz (LAN, 4 UV/VIS channels with Dl=100 nm)
Time Constants0.01 / 0.02 / 0.05 / 0.1 / 0.2 / 0.5 / 1.0 / 2.0 / 5.0 / 10.0 s
Integration TimeAutomatic