+51 997 777 980Lun–Vie 8:00–18:00 · Lima, Perú
Walz

PAM-2500

PAM-2500 — Walz
Marca
Walz
Categoría
Fluorometros
Disponibilidad
Consultar · respuesta en 24 h

The fastest portable PAM fluorometer with 10 µs time resolution. Resolves OJIP rise and saturation pulse analysis in one compact, Bluetooth-enabled field instrument. Downloads Product General Events Meetings Webinars Company About Us History Company Founder News Jobs

Ficha técnica del fabricante →

Especificaciones técnicas

VersionGeneral information
Signal detectionPIN-photodiode protected by long-pass filter (T
Power supplyRechargeable sealed lead-acid battery 12 V/2 Ah; Battery Charger MINI-PAM/L (100 to 240 V AC)
Operating temperature-5 to +40 °C
Dimensions23 cm x 10.5 cm x 10.5 cm (L x W x H) aluminum housing
Weight2.5 kg (including battery)
Measuring lightRed LEDs, maximum emission at 630 nm, FWHM (full width at half maximum) 20 nm. 1 μs pulses at modulation frequencies 10 to 5000 Hz for F
Far-red lightLED, maximum emission at 750 nm, FWHM 25 nm, 20 intensity levels
DesignFlexible, steel-spiral, plastic-covered bundle with three-pin optical connector
Weight300 g
DesignMetal clip with fiber holder and 11 mm diameter sample hole: 5.5 cm x 1.4 cm (L x W)
Fiber holder1.2 cm length, mounted 0.7 cm above base, with lateral screw to fix fiber optics. Angle between fiber optics axis and sample plane: 60°. Two spacer rings to vary the distance between fiber end and leaf surface
Input100 to 240 V AC, 47 to 63 Hz
Output19 V DC, 3.7 A
Operating temperature0 to 40 °C
Dimensions15 cm x 6 cm x 3 cm (L x W x H)
DesignAluminum box with custom foam packing
Dimensions60 cm x 40 cm x 25 cm (L x W x H)
Weight5 kg
ThermocoupleNi-CrNi, 0.1 mm diameter,
OutputPAR, high sensitivity range: 0 to 1000 µmol/(m
Power supplyPAM-2500 leaf clip socket (5 V/4 mA)
Dimensions16 cm x 3 cm x 1.7 cm (L x W x H)
Weight220 g
ThermocoupleNi-CrNi, diameter 0.1 mm, -20 to +60 °C
OutputPAR, high sensitivity range: 0 to 1000 μmol m
Cable length100 cm
Dimensions17 cm x 5.7 cm (max.) x 8 cm (max.) (L x W x H)
Weight310 g
Weight125 g
DesignAluminum plate (6.0 x 3.3 cm max.) with 11 mm diameter circular hole (measuring area) and aluminum port to position fiber at an angle of 60° relative to the aluminum plate. With port for temperature sensor of 2060-M unit to measure surface temperature and thread to mount the PAR sensor of the 2060-M
DesignAluminum clip with 3.2 mm diameter viewing area designed to position small leaves below the fiberoptics of the MINI-PAM-II, prepared to accommodate PAR and temperature sensors of the Mini Quantum/Temp.-Sensor 2065-M
Dimensions7.6 cm x 3.0 cm (max.) x 5.2 cm (max.) (L x W x H)
Weight55 g
DesignClip made of aluminum with felt contact areas and sliding shutter
Dimensions6.5 cm x 2 cm (max.) x 1.5 cm (max.) (L x W x H)
Weight3.6 g
DesignTube-shaped fiber tip holder composed of polyoxymethylene (POM; 4.5 cm x 2.5 cm, L x D max,) with recessed permanent neodymium magnet. Spring steel band (0.3 mm thick, 1.5 cm wide) consisting of two arms (2 cm and 5 cm, respectively) which form a right angle. The leaf is positioned between the 2 cm
Design90 cm cable with fuse for over-current protection. The cable bypasses the internal battery of the PAM-2500 fluorometer and supplies voltage from an external 12 V battery directly to the electronics. External DC cable to connect 12 V battery. One red and one black (GND)
Weight45 g

También en Fluorometros

Cotización en menos de 24 h

Cotiza este equipo

Cotizar: PAM-2500

WhatsApp